Projectors:Organized by Oldest to Newest

Room Issues Model Filter Lamps Spares Date Entered By:
All Auditorium Filters cleaned and scrolled. Put Spare into house left lamp 2 House left and CTR 2000+. House right does not recognize lamp 2. They all need a new set. no 1/19/2015 MG
Auditorium SR Lamp 2 exploded around 1,000 hours. Replaced with spare that had similar hours. Eiki HDT-1000 10.11.14
Large Preschool Died. Replaced with new projector. Sony VPL-FH36/B 5200 New New Unknown 10.13.14
Large Elementary Replaced lamp 2, cleaned Eiki 5000 cleaned #1 1425, #2- new 2 used #1s upstairs. No #2s on site. 05.03.16 SQ
Fusion Warning lights. One Lamp replaced with spare. Ordered two new lamps. (Possible lamp circuit issue, will troubleshoot when new spares come in) Eiki 5000 2 spare #1 bulbs 11.3.14
Fusion Changed out projector with one from SM roadcase because the one that was up there had circuit lamp2 broken. Also put two new lamps in projector. Took the one that was up there to Household to get fixed. Eiki 5000 Cleaned filters 2 new lamps at 0 hours 2 spare #1 bulbs and 1 #2 bulbs 11.12.14
Auditorium HL Eiki HDT-1000 6 scrolls left Lamp 1, 2 1535 Hr. No spare lamps that I know of 12.1.14 BC
Auditorium HR Eiki HDT-1000 7 scrolls left Lamp 1 1304 Lamp 2 1096 Hr. No spare lamps that I know of 12.1.14 BC
Auditorium Center Eiki – HDT-1000 6 scrolls left Lamp 1, 2 1886 Hr. No spare lamps that I know of 12.1.14 BC
All auditorium All lamps new 3 spares upstairs 3.4.15 MG
Auditorium, HR Eiki – HDT-1000 Lamp exploded 300 hours 8.6.15 MG
Fusion lamp2 doesnt fire. circuit issue 10.1.15 SQ and MG
Auditorium HR
Lamp1 powered down after a few minutes and showed a red x in the menu. 640 hours. Replaced with new.
1.9.16 Mg
Auditorium HL Changed lamp 1 7.1.15 MG
Fusion Replaced Projector Canon WUX 6010 3.1.17 MG
Auditorium Replaced CTR Lamp #2 Eiki – HDT-1000 Lamp 1 Hrs: 2500 Lamp 2 Hrs: 0 6.19.17 LE
Auditorium HR Eiki – HDT-1000 Lamp 1 Hrs: 1031 Lamp 2 Hrs: —- 6.19.17 LE
Auditorium HL Eiki – HDT-1000 Lamp 1 Hrs: 998 Lamp 2 Hrs: 2464 6.19.17 LE
Auditorium Eiki – HDT-1000 All lamps new 6.28.17 LE
Auditorium Hours Check All Center-2318/2127

HL-2208, HR-2,132

10/29/19 MG

Lighting: Organized by Oldest to Newest

 

 

Fixture: Serial Number: Date of Issue: Issue: Solution: Date of Solution: Notes: Spares
Maintenance By:
Center (Backrow) ??? ??? Grinding Noises/Acting up Tested at PB ??? Found no issues while testing at PB. Sent to WH as Replacement SQ
ALL 11/6/19 Hours Check Towers:

SR-569,564

SL-537,570

Air-1978, 560

11/6/19 Hayden P.
All Flown Movers 11/6/19 Lamp Replacement All 5 flown mover lamps replaced 11/6/19 Brock W.